设计 · 钢
火灾下屈曲缺陷系数 α (EN 1993-1-2)
根据 EN 1993-1-2 第 4.2.3.2 条式 (4.6) 的火灾下钢柱弯曲屈曲缺陷系数 alpha:α = 0.65 · √(235 / (fy / MPa))。
- EN 1993-1-2:2005
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 20°C 时钢材屈服强度 | N/m² | ||
| 火灾下屈曲缺陷系数 | 1 | Result |
实例
= 355,000,000 N/m²
= 0.5289 1
Standard and source
- Standard
- EN 1993-1-2:2005
- Result
- in 1
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
检索将在 设计 › 钢 开始。
Miaknows the formula catalog and asks for what is missing.