设计 · 钢

火灾下屈曲缺陷系数 α (EN 1993-1-2)

  • 类型:属性
  • 版本1
  • 2026/11/21已审核

根据 EN 1993-1-2 第 4.2.3.2 条式 (4.6) 的火灾下钢柱弯曲屈曲缺陷系数 alpha:α = 0.65 · √(235 / (fy / MPa))。

α=0.65⋅235fy\displaystyle \alpha = 0.65 \cdot \sqrt{\frac{235}{f_{y}}}
  • EN 1993-1-2:2005
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

α

Formula and quantities

SymbolNameUnitNote
fy\displaystyle f_{y}20°C 时钢材屈服强度N/m²
α\displaystyle \alpha火灾下屈曲缺陷系数1Result

实例

fy\displaystyle f_{y} = 355,000,000 N/m²

α\displaystyle \alpha = 0.5289 1

Standard and source

Standard
EN 1993-1-2:2005
Result
α\displaystyle \alpha in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
α\displaystyle \alpha = 0.528851 1= 0.65 · sqrt(235 / ((355,000,000 N/m²) / [MPa]))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

检索将在 设计 › 钢 开始。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.