设计 · 钢
工字钢截面阴影效应修正系数 ksh (EN 1993-1-2)
根据 EN 1993-1-2 第 4.2.5.1 条式 (4.26a) 的名义火灾下无保护工字钢截面阴影效应修正系数:ksh = 0.9 · (Sfb / Sf)。
- EN 1993-1-2:2005
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 包络箱形截面系数 [Am/V]_b | m⁻¹ | ||
| 实际截面系数 Am/V | m⁻¹ | ||
| 阴影效应修正系数 | 1 | Result |
实例
= 167 m⁻¹ · = 216 m⁻¹
= 0.6958 1
Standard and source
- Standard
- EN 1993-1-2:2005
- Result
- in 1
Reference to clause and equation, no standard text. The description is written in our own words.