设计 · 钢
无保护钢材温升 ΔΘ,a (EN 1993-1-2)
根据 EN 1993-1-2 第 4.2.5.1 条式 (4.25) 在时间步长 Δt 内无保护钢构件的温升:Δθa,t = ksh · ((Sf / m⁻¹) / (ca · (ρa / (kg/m³)))) · hnet · (dt / s)。
- EN 1993-1-2:2005
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 阴影效应修正系数 | 1 | ||
| 截面系数 Am/V | m⁻¹ | ||
| 钢材比热容(J/(kg·K),例如 600) | 1 | ||
| 钢材密度(7850 kg/m³) | kg/m³ | ||
| 单位面积设计净热流密度(W/m²) | 1 | ||
| 时间步长(最大 5 s) | s | ||
| 钢材温升(K 或 °C) | 1 | Result |
实例
= 0.7 1 · = 200 m⁻¹ · = 600 1 · = 7,850 kg/m³ · = 50,000 1 · = 5 s
= 7.431 1
Standard and source
- Standard
- EN 1993-1-2:2005
- Result
- in 1
Reference to clause and equation, no standard text. The description is written in our own words.