设计 · 组合材料
部分抗剪连接最小连接度 ηmin (EN 1994-1-1)
根据 EN 1994-1-1 第 6.6.1.2 条式 (6.13) 跨度 Le <= 25 m 的等翼缘组合梁中延性栓钉连接件的最小部分抗剪连接度:ηmin = 1 - (355 / fy) · (0.75 - 0.03 · Le)。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 结构钢公称屈服强度,单位 MPa | 1 | ||
| 反弯点(零弯矩点)间距,单位 m (<= 25) | 1 | ||
| 最小抗剪连接度 (>= 0.40) | 1 | Result |
实例演算
S355 12 m span
= 355 · = 12
= 0.61
S355 20 m span
= 355 · = 20
= 0.85
Standard and source
- Standard
- EN 1994-1-1:2004,第6.6.1.2条,式(6.13)
- Result
- in 1
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.