部分せん断結合の最小結合度 ηmin (EN 1994-1-1)
EN 1994-1-1 第6.6.1.2項 式(6.13)によるスパン Le <= 25 m の等フランジ合成桁における延性頭付きスタッドの最小部分せん断結合度: ηmin = 1 - (355 / fy) · (0.75 - 0.03 · Le).
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 構造用鋼の公称降伏強度 MPa | 1 | ||
| 曲げモーメント零点間距離 m (<= 25) | 1 | ||
| 最小せん断結合度 (>= 0.40) | 1 | Result |
例題
S355 12 m span
= 355 · = 12
= 0.61
S355 20 m span
= 355 · = 20
= 0.85
Standard and source
- Standard
- EN 1994-1-1:2004、6.6.1.2項、式 (6.13)
- Result
- in 1