结构分析 · 柱和稳定性

侧移框架中柱的有效长度系数

  • 类型:属性
  • 版本1

依据 EN 1993-1-1 附录 E,侧移框架中柱的有效长度系数 beta 近似公式:β = √((1 - 0.2 · (η1 + η2) - 0.12 · η1 · η2) / (1 - 0.8 · (η1 + η2) + 0.6 · η1 · η2))。

β=1−0.2⋅(η1+η2)−0.12⋅η1⋅η21−0.8⋅(η1+η2)+0.6⋅η1⋅η2\displaystyle \beta = \sqrt{\frac{1 - 0.2 \cdot (\eta_{1} + \eta_{2}) - 0.12 \cdot \eta_{1} \cdot \eta_{2}}{1 - 0.8 \cdot (\eta_{1} + \eta_{2}) + 0.6 \cdot \eta_{1} \cdot \eta_{2}}}
  • General formula, independent of standards
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

β

Formula and quantities

SymbolNameUnitNote
η1\displaystyle \eta_{1}端部 1 的节点分配系数–
η2\displaystyle \eta_{2}端部 2 的节点分配系数–
β\displaystyle \beta有效长度系数–Result

实例

η1\displaystyle \eta_{1} = 0 · η2\displaystyle \eta_{2} = 0

β\displaystyle \beta = 1 · Source: sqrt(1.0 / 1.0) = 1.0

Scope and standard

无支撑/侧移建筑框架中的柱。

Result
β\displaystyle \beta (dimensionless)

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

β\displaystyle \beta = 1= sqrt((1 - 0.2 · (0 + 0) - 0.12 · 0 · 0) / (1 - 0.8 · (0 + 0) + 0.6 · 0 · 0))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

检索将在 结构分析 › 柱和稳定性 开始。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.