構造解析 · 柱と安定性

変形架構における柱の有効長係数

  • タイプ:特性値
  • バージョン1

EN 1993-1-1付属書Eによる変形架構内の柱の有効長係数 beta の近似式:β = √((1 - 0.2 · (η1 + η2) - 0.12 · η1 · η2) / (1 - 0.8 · (η1 + η2) + 0.6 · η1 · η2))。

β=1−0.2⋅(η1+η2)−0.12⋅η1⋅η21−0.8⋅(η1+η2)+0.6⋅η1⋅η2\displaystyle \beta = \sqrt{\frac{1 - 0.2 \cdot (\eta_{1} + \eta_{2}) - 0.12 \cdot \eta_{1} \cdot \eta_{2}}{1 - 0.8 \cdot (\eta_{1} + \eta_{2}) + 0.6 \cdot \eta_{1} \cdot \eta_{2}}}
  • General formula, independent of standards
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

β

Formula and quantities

SymbolNameUnitNote
η1\displaystyle \eta_{1}端部1の接合分配係数–
η2\displaystyle \eta_{2}端部2の接合分配係数–
β\displaystyle \beta有効長係数–Result

例題

η1\displaystyle \eta_{1} = 0 · η2\displaystyle \eta_{2} = 0

β\displaystyle \beta = 1 · Source: sqrt(1.0 / 1.0) = 1.0

Scope and standard

アンブレースド/変形建物架構内の柱。

Result
β\displaystyle \beta (dimensionless)

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

β\displaystyle \beta = 1= sqrt((1 - 0.2 · (0 + 0) - 0.12 · 0 · 0) / (1 - 0.8 · (0 + 0) + 0.6 · 0 · 0))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

検索は構造解析 › 柱と安定性で開始されます。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.