Design · Composite
Effective flexural stiffness of composite column (EI)_eff
Short-term effective flexural stiffness of a composite column section for elastic critical load: (EI)_eff = Ea · Ia + Es · Is + 0.6 · Ecm · Ic.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Modulus of elasticity of structural steel | N/m² | ||
| Second moment of area of structural steel section | cm⁴ | ||
| Modulus of elasticity of reinforcing steel | N/m² | ||
| Second moment of area of reinforcement | cm⁴ | ||
| Secant modulus of elasticity of concrete | N/m² | ||
| Second moment of area of uncracked concrete section | cm⁴ | ||
| Effective flexural stiffness | kN·m² | Result |
Worked example
= 210,000,000,000 N/m² · = 14,920 cm⁴ · = 200,000,000,000 N/m² · = 3,200 cm⁴ · = 33,000,000,000 N/m² · = 198,400 cm⁴
= 77,015.2 kN·m²
Standard and source
- Standard
- EN 1994-1-1:2004
- Result
- in kN*m²
Reference to clause and equation, no standard text. The description is written in our own words.