Design · Composite

Effective width of concrete flange beff

  • Type: Property
  • Version 1
  • reviewed on 11/13/2026

Total effective width of the concrete flange for a composite beam at mid-span or internal support: beff = b0 + be1 + be2.

beff=b0+be1+be2\displaystyle b_{\mathrm{eff}} = b_{0} + b_{e1} + b_{e2}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

beff

Formula and quantities

SymbolNameUnitNote
b0\displaystyle b_{0}Distance between centres of outstand shear connectorsmm
be1\displaystyle b_{e1}Effective width of concrete flange on side 1mm
be2\displaystyle b_{e2}Effective width of concrete flange on side 2mm
beff\displaystyle b_{\mathrm{eff}}Total effective width of concrete flangemmResult

Worked example

b0\displaystyle b_{0} = 120 mm · be1\displaystyle b_{e1} = 1,000 mm · be2\displaystyle b_{e2} = 1,000 mm

beff\displaystyle b_{\mathrm{eff}} = 2,120 mm

Standard and source

Result
beff\displaystyle b_{\mathrm{eff}} in mm

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
beff\displaystyle b_{\mathrm{eff}} = 2,120 mm= (120 mm) + (1,000 mm) + (1,000 mm)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Composite.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.