Design · Composite
Reduction factor for studs in profiled sheeting kt
Reduction factor for headed studs in profiled steel sheeting with ribs transverse to the supporting beam: kt = (0.7 / √(nr)) · (b0 / hp) · (hsc / hp - 1).
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Number of studs in one rib at a beam intersection | 1 | ||
| Mean width of concrete rib | mm | ||
| Overall depth of profiled steel sheeting | mm | ||
| Overall nominal height of headed stud | mm | ||
| Sheeting reduction factor for stud resistance | 1 | Result |
Worked example
= 1 · = 100 mm · = 58 mm · = 100 mm
= 0.874
Standard and source
- Standard
- EN 1994-1-1:2004
- Result
- in 1
Reference to clause and equation, no standard text. The description is written in our own words.