Design · Concrete

Minimum shear reinforcement ratio for beams

  • Type: Coefficient
  • Version 1
  • reviewed on 11/9/2026

Minimum shear reinforcement ratio for beams according to EN 1992-1-1: ρw,min = 0.08 · √(fck / MPa) / (fyk / MPa).

ρw,min=0.08⋅fckfyk\displaystyle \rho_{w,\mathrm{min}} = 0.08 \cdot \frac{\sqrt{f_{ck}}}{f_{yk}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

fyk

Formula and quantities

SymbolNameUnitNote
fck\displaystyle f_{ck}Characteristic compressive strength of concreteN/mm²
fyk\displaystyle f_{yk}Characteristic yield strength of shear reinforcementN/mm²
ρw,min\displaystyle \rho_{w,\mathrm{min}}Minimum shear reinforcement ratio–Result

Worked example

fck\displaystyle f_{ck} = 30 N/mm² · fyk\displaystyle f_{yk} = 500 N/mm²

ρw,min\displaystyle \rho_{w,\mathrm{min}} = 0.000876 · Source: EN 1992-1-1:2004 Eq. (9.5N)

Scope and standard

Beams requiring shear reinforcement according to EN 1992-1-1, clause 9.2.2 (5).

Standard
EN 1992-1-1:2004, clause 9.2.2 (5), Eq. (9.5N)
Result
ρw,min\displaystyle \rho_{w,\mathrm{min}} (dimensionless)

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
ρw,min\displaystyle \rho_{w,\mathrm{min}} = 0.000876356= 0.08 · sqrt((30 N/mm²) / [N/mm²]) / ((500 N/mm²) / [N/mm²])

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Concrete.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.