Design · Concrete

Required tensile reinforcement for bending

  • Type: Resistance
  • Version 1
  • reviewed on 11/9/2026

Required cross-sectional area of tensile reinforcement for pure bending: As,req = MEd / (z · fyd).

As,req=MEd/(z⋅fyd)\displaystyle A_{s,req} = M_{\mathrm{Ed}} / (z \cdot f_{yd})
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

zAs,reqMEdfyd

Formula and quantities

SymbolNameUnitNote
MEd\displaystyle M_{\mathrm{Ed}}Design bending momentNm
z\displaystyle zInternal lever armm
fyd\displaystyle f_{yd}Design yield strength of reinforcementN/mm²
As,req\displaystyle A_{s,req}Required area of tensile reinforcementm²Result

Worked example

MEd\displaystyle M_{\mathrm{Ed}} = 150,000 Nm · z\displaystyle z = 0.46 m · fyd\displaystyle f_{yd} = 434.783 N/mm²

As,req\displaystyle A_{s,req} = 0.00075 m² · Source: hand calculation

Scope and standard

Beams and slabs under pure flexure with tension steel yielding at ULS.

Standard
EN 1992-1-1:2004, clause 6.1
Result
As,req\displaystyle A_{s,req} in m²

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
As,req\displaystyle A_{s,req} = 0.000749999 m²= (150,000 Nm) / ((0.46 m) · (434.783 N/mm²))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Concrete.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.