Design · Concrete
Required tensile reinforcement for bending
Required cross-sectional area of tensile reinforcement for pure bending: As,req = MEd / (z · fyd).
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Design bending moment | Nm | ||
| Internal lever arm | m | ||
| Design yield strength of reinforcement | N/mm² | ||
| Required area of tensile reinforcement | m² | Result |
Worked example
= 150,000 Nm · = 0.46 m · = 434.783 N/mm²
= 0.00075 m² · Source: hand calculation
Scope and standard
Beams and slabs under pure flexure with tension steel yielding at ULS.
- Standard
- EN 1992-1-1:2004, clause 6.1
- Result
- in m²
Reference to clause and equation, no standard text. The description is written in our own words.