Design · Concrete
Required shear reinforcement area per unit length
Required ratio of stirrup cross-section area to spacing: asw = Asw / s = VEd / (z · fywd · cotθ).
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Design shear force | kN | ||
| Internal lever arm | m | ||
| Design yield strength of shear reinforcement | N/mm² | ||
| Cotangent of strut inclination angle theta | – | ||
| Required shear reinforcement area per unit length | m | Result |
Worked example
= 250 kN · = 0.45 m · = 434.783 N/mm² · = 2.5
= 0.0005111 m · Source: hand calculation
Scope and standard
Beams with vertical shear links (alpha = 90 deg) according to EN 1992-1-1, clause 6.2.3.
- Standard
- EN 1992-1-1:2004, clause 6.2.3 (3)
- Result
- in cm²/m
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Calculate for my memberwith Mia in CALC
- Compare with RFEM/RSTAB resultshand calculation versus model
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Design › Concrete.
Miaknows the formula catalog and asks for what is missing.