Design · Concrete

Reference reinforcement ratio ρ0

  • Type: Property
  • Version 1
  • reviewed on 11/12/2026

Reference reinforcement ratio for span-to-depth ratio calculation to EN 1992-1-1 Clause 7.4.2 (2): ρ0 = 10⁻³ · √(fck).

ρ0=10−3⋅fck\displaystyle \rho_{0} = 10^{-3} \cdot \sqrt{f_{ck}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

fck

Formula and quantities

SymbolNameUnitNote
fck\displaystyle f_{ck}Characteristic concrete compressive cylinder strengthN/m²
ρ0\displaystyle \rho_{0}Reference reinforcement ratio1Result

Worked example

fck\displaystyle f_{ck} = 25,000,000 N/m²

ρ0\displaystyle \rho_{0} = 0.005 1 · Source: EN 1992-1-1:2004 clause 7.4.2 (2)

Scope and standard

Reinforced concrete beams and slabs to EN 1992-1-1.

Standard
EN 1992-1-1:2004, clause 7.4.2 (2)
Result
ρ0\displaystyle \rho_{0} in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
ρ0\displaystyle \rho_{0} = 0.005 1= 0.001 · sqrt((25,000,000 N/m²) / 1 [MPa])

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Concrete.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.