Reduced effective depth by 500°C isotherm method (EN 1992-1-2)
Reduced effective depth dfi of a concrete beam or slab exposed to fire on the compression or tension face according to EN 1992-1-2 Annex B.1: dfi = d - a500.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Original effective depth | mm | ||
| Depth of 500°C isotherm from fire-exposed compression face | mm | ||
| Reduced effective depth in fire | mm | Result |
Worked example
= 550 mm · = 35 mm
= 515 mm
Standard and source
- Standard
- EN 1992-1-2:2004
- Result
- in mm
Reference to clause and equation, no standard text. The description is written in our own words.