设计 · 混凝土

基准配筋率 ρ0

  • 类型:属性
  • 版本1
  • 2026/11/12已审核

跨高比计算的基准配筋率,按 EN 1992-1-1 第 7.4.2 (2) 条: ρ0 = 10⁻³ · √(fck)。

ρ0=10−3⋅fck\displaystyle \rho_{0} = 10^{-3} \cdot \sqrt{f_{ck}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

fck

Formula and quantities

SymbolNameUnitNote
fck\displaystyle f_{ck}混凝土圆柱体抗压强度标准值N/m²
ρ0\displaystyle \rho_{0}基准配筋率1Result

实例

fck\displaystyle f_{ck} = 25,000,000 N/m²

ρ0\displaystyle \rho_{0} = 0.005 1 · Source: EN 1992-1-1:2004 第 7.4.2 条 (2)

Scope and standard

按 EN 1992-1-1 的钢筋混凝土梁和板。

Standard
EN 1992-1-1:2004,第7.4.2 (2)条
Result
ρ0\displaystyle \rho_{0} in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
ρ0\displaystyle \rho_{0} = 0.005 1= 0.001 · sqrt((25,000,000 N/m²) / 1 [MPa])

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

检索将在 设计 › 混凝土 开始。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.