Design · Concrete
Reduced concrete width by 500°C isotherm method (EN 1992-1-2)
Reduced effective width bfi of a concrete beam or column exposed to fire on both sides according to the 500°C isotherm method in EN 1992-1-2 Annex B.1: bfi = b - 2 · a500.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Original cross-section width | mm | ||
| Depth of 500°C isotherm from fire-exposed side | mm | ||
| Reduced effective concrete width in fire | mm | Result |
Worked example
= 300 mm · = 30 mm
= 240 mm
Standard and source
- Standard
- EN 1992-1-2:2004
- Result
- in mm
Reference to clause and equation, no standard text. The description is written in our own words.