设计 · 混凝土
火灾下混凝土抗压设计强度 fcd,fi (EN 1992-1-2)
根据 EN 1992-1-2 第 2.3 条式 (2.2) 的高温下混凝土抗压设计强度:fcdfi = (kc · fck) / γMfi。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 混凝土抗压强度高温折减系数 | 1 | ||
| 混凝土圆柱体抗压强度标准值 | N/m² | ||
| 火灾下混凝土分项系数(通常取 1.0) | 1 | ||
| 火灾下混凝土抗压设计强度 | N/m² | Result |
实例
= 0.6 1 · = 30,000,000 N/m² · = 1 1
= 18,000,000 N/m²
Standard and source
- Standard
- EN 1992-1-2:2004
- Result
- in MPa
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
检索将在 设计 › 混凝土 开始。
Miaknows the formula catalog and asks for what is missing.