Actions and loads · Accidental actions
Reduction factor for design load level in fire ηfi (EN 1991-1-2)
Simplified reduction factor ηfi relating the design effect of actions in fire to the normal-temperature ULS design effect according to EN 1991-1-2 / Eurocode 2 & 3 Clause 2.4.2: ηfi = (Gk + ψfi · Qk1) / (γG · Gk + γQ · Qk1).
- EN 1991-1-2:2002
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Characteristic permanent action | kN | ||
| Characteristic leading variable action | kN | ||
| Combination factor for fire (psi_1,1 or psi_2,1) | 1 | ||
| Partial factor for permanent action (typically 1.35) | 1 | ||
| Partial factor for variable action (typically 1.50) | 1 | ||
| Fire design load level reduction factor | 1 | Result |
Worked example
= 100 kN · = 60 kN · = 0.3 1 · = 1.35 1 · = 1.5 1
= 0.5244 1
Standard and source
- Standard
- EN 1991-1-2:2002
- Result
- in 1
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Calculate for my dimensionsenter values, check the result
- Compare with a catalog sectionformula value and table value
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Actions and loads › Accidental actions.
Miaknows the formula catalog and asks for what is missing.