Insulating glass unit load sharing on outer pane
Share of external surface load q carried by outer pane 1 in a double-glazing insulating glass unit with stiffness share δ1 and cavity factor φigu: q1 = (δ1 + (1 - δ1) · (1 - φigu)) · q.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Stiffness share of outer pane (h_1^3 / (h_1^3 + h_2^3)) | 1 | ||
| Insulating glass unit cavity factor (0 to 1) | 1 | ||
| External surface load on outer pane | N/m² | ||
| Load carried by outer pane | N/m² | Result |
Worked example
= 0.5 · = 0.7 · = 2,000 N/m²
= 1,300 N/m²
Standard and source
- Standard
- EN 16612:2019
- Result
- in kPa
Reference to clause and equation, no standard text. The description is written in our own words.