Design · Glass

Insulating glass unit cavity factor φ (EN 16612)

  • Type: Property
  • Version 1
  • reviewed on 11/25/2026

Insulating glass unit factor phi governing cavity pressure coupling between panes according to EN 16612 Clause 7.3.2: φIGU = 1 / (1 + (a / astar)⁴).

ϕIGU=1/(1+(a/astar)4)\displaystyle \phi _{IGU} = 1 / (1 + (a / a_{star})^4)
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

φIGU

Formula and quantities

SymbolNameUnitNote
a\displaystyle aShorter pane span lengthmm
astar\displaystyle a_{star}Characteristic length of insulating glass unitmm
ϕIGU\displaystyle \phi_{IGU}Insulating glass unit factor1Result

Worked example

a\displaystyle a = 600 mm · astar\displaystyle a_{star} = 480 mm

ϕIGU\displaystyle \phi_{IGU} = 0.290579

Standard and source

Result
ϕIGU\displaystyle \phi_{IGU} in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
ϕIGU\displaystyle \phi_{IGU} = 0.290579 1= 1 / (1 + ((600 mm) / (480 mm))⁴)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Glass.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.