Design · Glass

IGU load share on inner pane

  • Type: Property
  • Version 1
  • reviewed on 11/15/2026

External load fraction carried by the inner pane of a double insulating glass unit based on pane flexibilities according to EN 16612 Annex C: q2 = (δ1 / (δ1 + δ2)) · qext.

q2=δ1δ1+δ2⋅qext\displaystyle q_{2} = \frac{\delta_{1}}{\delta_{1} + \delta_{2}} \cdot q_{ext}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

q2

Formula and quantities

SymbolNameUnitNote
δ1\displaystyle \delta_{1}Flexibility factor of outer pane1
δ2\displaystyle \delta_{2}Flexibility factor of inner pane1
qext\displaystyle q_{ext}External surface loadN/m²
q2\displaystyle q_{2}Load on inner paneN/m²Result

Worked example

δ1\displaystyle \delta_{1} = 1 1 · δ2\displaystyle \delta_{2} = 1 1 · qext\displaystyle q_{ext} = 1,000 N/m²

q2\displaystyle q_{2} = 500 N/m²

Standard and source

Result
q2\displaystyle q_{2} in Pa

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
q2\displaystyle q_{2} = 500 N/m²= ((1 1) / ((1 1) + (1 1))) · (1,000 N/m²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Glass.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.