Actions and loads · Seismic actions
Interstorey drift sensitivity coefficient (P-Δ)
Interstorey drift sensitivity coefficient for assessing second-order effects: θ = (Ptot · dr) / (Vtot · h).
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Total gravity load at and above the storey | kN | ≥ 0 | |
| Design interstorey drift | mm | ≥ 0 | |
| Total seismic storey shear | kN | > 0 | |
| Interstorey height | mm | > 0 | |
| Drift sensitivity coefficient | – | Result |
Worked example
= 8,000 kN · = 15 mm · = 500 kN · = 3,000 mm
= 0.08 · Source: hand calculation
Scope and standard
EN 1998-1, clause 4.4.2.2 (second-order effects negligible if theta <= 0.10).
- Standard
- EN 1998-1:2004, clause 4.4.2.2, Eq. (4.28)
- Result
- (dimensionless)
Reference to clause and equation, no standard text. The description is written in our own words.