Actions and loads · Snow loads

Snow load overhanging roof eaves

  • Type: Action
  • Version 1
  • reviewed on 11/10/2026

Linear design load per meter caused by snow overhanging the edge of a roof according to EN 1991-1-3 Clause 6.3 Eq. (6.1).

se=k⋅s2/γ\displaystyle s_{e} = k \cdot s^2 / \gamma
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

se

Formula and quantities

SymbolNameUnitNote
k\displaystyle kIrregular snow overhang coefficient–
s\displaystyle sSnow load on roofkN/m²
γ\displaystyle \gammaSnow unit weightkN/m³
se\displaystyle s_{e}Linear snow load on eaveskN/mResult

Worked example

k\displaystyle k = 3 · s\displaystyle s = 2 kN/m² · γ\displaystyle \gamma = 3 kN/m³

se\displaystyle s_{e} = 4 kN/m

Standard and source

Standard
EN 1991-1-3:2003, clause 6.3
Result
se\displaystyle s_{e} in kN/m

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
se\displaystyle s_{e} = 4 kN/m= 3 · (2 kN/m²)² / (3 kN/m³)