Design · Steel

T-stub design tension resistance Mode 3 FT,3,Rd

  • Type: Resistance
  • Version 1
  • reviewed on 11/10/2026

T-stub design tension resistance for failure Mode 3 (pure bolt failure) according to EN 1993-1-8 Table 6.2: FT,3,Rd = nb · Ft,Rd.

FT,3,Rd=nb⋅Ft,Rd\displaystyle F_{T,3,\mathrm{Rd}} = n_{\mathrm{b}} \cdot F_{t,\mathrm{Rd}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

FT3RdFtRdnb

Formula and quantities

SymbolNameUnitNote
nb\displaystyle n_{\mathrm{b}}Number of bolts in row1
Ft,Rd\displaystyle F_{t,\mathrm{Rd}}Design tension resistance per boltkN
FT,3,Rd\displaystyle F_{T,3,\mathrm{Rd}}Mode 3 design tension resistancekNResult

Worked example

nb\displaystyle n_{\mathrm{b}} = 2 · Ft,Rd\displaystyle F_{t,\mathrm{Rd}} = 176.4 kN

FT,3,Rd\displaystyle F_{T,3,\mathrm{Rd}} = 352.8 kN

Standard and source

Result
FT,3,Rd\displaystyle F_{T,3,\mathrm{Rd}} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
FT,3,Rd\displaystyle F_{T,3,\mathrm{Rd}} = 352.8 kN= (2 1) · (176.4 kN)

Continue with Mia