Design · Steel
Design resistance per unit length of fillet weld Fw,Rd
Design resistance of a fillet weld per unit length using the simplified method: Fw,Rd = a · fvw,d.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Throat thickness of fillet weld | mm | ||
| Design shear strength of weld | N/mm² | ||
| Design resistance per unit length | kN/m | Result |
Worked example
= 5 mm · = 207.846 N/mm²
= 1,039.23 kN/m · Source: EN 1993-1-8:2005 Eq. (4.3)
Scope and standard
Fillet welds in any orientation using the simplified method (EN 1993-1-8, clause 4.5.3.3).
- Standard
- EN 1993-1-8:2005, clause 4.5.3.3 (1), Eq. (4.3)
- Result
- in kN/m
Reference to clause and equation, no standard text. The description is written in our own words.