Design · Steel

Design shear strength of fillet weld fvw,d

  • Type: Property
  • Version 1
  • reviewed on 11/9/2026

Design shear strength of a fillet weld according to the simplified method: fvw,d = fu / (√(3) · βw · γM2).

fvw,d=fu3⋅βw⋅γM2\displaystyle f_{vw,\mathrm{d}} = \frac{f_{u}}{\sqrt{3} \cdot \beta_{w} \cdot \gamma_{\mathrm{M2}}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

fufvw,dβw

Formula and quantities

SymbolNameUnitNote
fu\displaystyle f_{u}Nominal ultimate tensile strength of weaker partN/mm²
βw\displaystyle \beta_{w}Correlation factor for fillet weld–
γM2\displaystyle \gamma_{\mathrm{M2}}Partial factor for connections–
fvw,d\displaystyle f_{vw,\mathrm{d}}Design shear strength of weldN/mm²Result

Worked example

fu\displaystyle f_{u} = 360 N/mm² · βw\displaystyle \beta_{w} = 0.8 · γM2\displaystyle \gamma_{\mathrm{M2}} = 1.25

fvw,d\displaystyle f_{vw,\mathrm{d}} = 207.846 N/mm² · Source: EN 1993-1-8:2005 Eq. (4.4)

Scope and standard

Fillet welded connections according to EN 1993-1-8, clause 4.5.3.3.

Standard
EN 1993-1-8:2005, clause 4.5.3.3 (1), Eq. (4.4)
Result
fvw,d\displaystyle f_{vw,\mathrm{d}} in N/mm²

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
fvw,d\displaystyle f_{vw,\mathrm{d}} = 207.846 N/mm²= (360 N/mm²) / (sqrt(3) · 0.8 · 1.25)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Steel.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.