Design · Steel
Design tension resistance of bolt Ft,Rd
Design tension resistance of a bolt: Ft,Rd = k2 · fub · As / γM2.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Bolt factor | – | ||
| Ultimate tensile strength of bolt | N/mm² | ||
| Tensile stress area of bolt | m² | ||
| Partial factor for connections | – | ||
| Design tension resistance | kN | Result |
Worked example
= 0.9 · = 800 N/mm² · = 0.000245 m² · = 1.25
= 141.12 kN · Source: EN 1993-1-8:2005 Table 3.4
Scope and standard
Bolted connections in tension according to EN 1993-1-8, Table 3.4 (k_2 = 0.9 for standard bolts).
- Standard
- EN 1993-1-8:2005, clause 3.6.1, Eq. Table 3.4
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.