Design · Connections

Total fillet weld force resistance Fw,Rd,tot

  • Type: Resistance
  • Version 1
  • reviewed on 11/13/2026

Total design resistance of a steel fillet weld of throat thickness a and effective length leff: Fw,Rd,tot = a · leff · fvw,d.

Fw,Rd,tot=a⋅leff⋅fvw,d\displaystyle F_{w,\mathrm{Rd},tot} = a \cdot l_{\mathrm{eff}} \cdot f_{vw,\mathrm{d}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

aleff

Formula and quantities

SymbolNameUnitNote
a\displaystyle aEffective throat thickness of fillet weldmm
leff\displaystyle l_{\mathrm{eff}}Effective length of fillet weldmm
fvw,d\displaystyle f_{vw,\mathrm{d}}Design shear strength of fillet weldN/m²
Fw,Rd,tot\displaystyle F_{w,\mathrm{Rd},tot}Total design weld force resistancekNResult

Worked example

a\displaystyle a = 5 mm · leff\displaystyle l_{\mathrm{eff}} = 180 mm · fvw,d\displaystyle f_{vw,\mathrm{d}} = 261,730,000 N/m²

Fw,Rd,tot\displaystyle F_{w,\mathrm{Rd},tot} = 235.56 kN

Standard and source

Result
Fw,Rd,tot\displaystyle F_{w,\mathrm{Rd},tot} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Fw,Rd,tot\displaystyle F_{w,\mathrm{Rd},tot} = 235.557 kN= (5 mm) · (180 mm) · (261,730,000 N/m²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Connections.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.