設計 · 接合部

すみ肉溶接の全耐力 Fw,Rd,tot

  • タイプ:耐力
  • バージョン1
  • 2026/11/13にレビュー済み

のど厚 a・有効長さ leff の鋼構造すみ肉溶接の全設計耐力: Fw,Rd,tot = a · leff · fvw,d。

Fw,Rd,tot=a⋅leff⋅fvw,d\displaystyle F_{w,\mathrm{Rd},tot} = a \cdot l_{\mathrm{eff}} \cdot f_{vw,\mathrm{d}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

aleff

Formula and quantities

SymbolNameUnitNote
a\displaystyle aすみ肉溶接の有効のど厚mm
leff\displaystyle l_{\mathrm{eff}}すみ肉溶接の有効長さmm
fvw,d\displaystyle f_{vw,\mathrm{d}}すみ肉溶接の設計せん断強度N/m²
Fw,Rd,tot\displaystyle F_{w,\mathrm{Rd},tot}溶接の全設計耐力kNResult

例題

a\displaystyle a = 5 mm · leff\displaystyle l_{\mathrm{eff}} = 180 mm · fvw,d\displaystyle f_{vw,\mathrm{d}} = 261,730,000 N/m²

Fw,Rd,tot\displaystyle F_{w,\mathrm{Rd},tot} = 235.56 kN

Standard and source

Result
Fw,Rd,tot\displaystyle F_{w,\mathrm{Rd},tot} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Fw,Rd,tot\displaystyle F_{w,\mathrm{Rd},tot} = 235.557 kN= (5 mm) · (180 mm) · (261,730,000 N/m²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

検索は設計 › 接合部で開始されます。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.