설계 · 접합부

필릿 용접 총 내력 Fw,Rd,tot

  • 유형: 저항
  • 버전 1
  • 2026. 11. 13.에 검토됨

목두께 a, 유효길이 leff인 강구조 필릿 용접의 총 설계 내력: Fw,Rd,tot = a · leff · fvw,d.

Fw,Rd,tot=a⋅leff⋅fvw,d\displaystyle F_{w,\mathrm{Rd},tot} = a \cdot l_{\mathrm{eff}} \cdot f_{vw,\mathrm{d}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

aleff

Formula and quantities

SymbolNameUnitNote
a\displaystyle a필릿 용접의 유효 목두께mm
leff\displaystyle l_{\mathrm{eff}}필릿 용접의 유효 길이mm
fvw,d\displaystyle f_{vw,\mathrm{d}}필릿 용접의 설계 전단강도N/m²
Fw,Rd,tot\displaystyle F_{w,\mathrm{Rd},tot}용접의 총 설계 내력kNResult

예제

a\displaystyle a = 5 mm · leff\displaystyle l_{\mathrm{eff}} = 180 mm · fvw,d\displaystyle f_{vw,\mathrm{d}} = 261,730,000 N/m²

Fw,Rd,tot\displaystyle F_{w,\mathrm{Rd},tot} = 235.56 kN

Standard and source

Result
Fw,Rd,tot\displaystyle F_{w,\mathrm{Rd},tot} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Fw,Rd,tot\displaystyle F_{w,\mathrm{Rd},tot} = 235.557 kN= (5 mm) · (180 mm) · (261,730,000 N/m²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

설계 › 접합부에서 검색이 시작됩니다.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.