Design · Timber

Effective charring depth def (EN 1995-1-2)

  • Type: Property
  • Version 1
  • reviewed on 11/21/2026

Effective charring depth for the reduced cross-section method adding the zero-strength layer according to EN 1995-1-2 Clause 4.2.2 Eq. (4.1): def = dcharn + k0 · d0.

def=dchar,n+k0⋅d0\displaystyle d_{\mathrm{ef}} = d_{\mathrm{char},n} + k_{0} \cdot d_{0}
  • EN 1995-1-2:2004
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

yzdefd0

Formula and quantities

SymbolNameUnitNote
dcharn\displaystyle d_{charn}Notional charring depthmm
k0\displaystyle k_{0}Zero-strength layer factor (1.0 for t >= 20 min)1
d0\displaystyle d_{0}Zero-strength layer thickness (7 mm)mm
def\displaystyle d_{\mathrm{ef}}Effective charring depthmmResult

Worked example

dcharn\displaystyle d_{charn} = 42 mm · k0\displaystyle k_{0} = 1 1 · d0\displaystyle d_{0} = 7 mm

def\displaystyle d_{\mathrm{ef}} = 49 mm

Standard and source

Standard
EN 1995-1-2:2004
Result
def\displaystyle d_{\mathrm{ef}} in mm

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
def\displaystyle d_{\mathrm{ef}} = 49 mm= (42 mm) + (1 1) · (7 mm)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Timber.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.