Design · Timber

Lateral-torsional buckling reduction factor kcrit (slender range)

  • Type: Coefficient
  • Version 1
  • reviewed on 11/10/2026

Lateral-torsional buckling reduction factor for relative slenderness λrel,m > 1.4 according to EN 1995-1-1 6.3.3 eq. 6.35: kcrit = 1 / λrel,m².

kcrit=1/λrel,m2\displaystyle k_{crit} = 1 / \lambda _{rel,m}^2
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

λrel,m

Formula and quantities

SymbolNameUnitNote
λrel,m\displaystyle \lambda_{rel,m}Relative slenderness for bending1
kcrit\displaystyle k_{crit}Reduction factor k_crit1Result

Worked example

λrel,m\displaystyle \lambda_{rel,m} = 1.6

kcrit\displaystyle k_{crit} = 0.3906

Standard and source

Result
kcrit\displaystyle k_{crit} in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

kcrit\displaystyle k_{crit} = 0.390625 1= 1 / (1.6 1)²