Actions et charges · Actions sismiques

Coefficient de sensibilité au déplacement entre niveaux (P-Δ)

  • Type : Coefficient
  • Version 1
  • revue le 13/11/2026

Coefficient de sensibilité au déplacement entre niveaux pour l'évaluation des effets du second ordre : θ = (Ptot · dr) / (Vtot · h).

θ=Ptot⋅drVtot⋅h\displaystyle \theta = \frac{P_{tot} \cdot d_{r}}{V_{tot} \cdot h}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

PtothVtotVtot

Formula and quantities

SymbolNameUnitNote
Ptot\displaystyle P_{tot}Charge gravitaire totale au niveau considéré et au-dessuskNPtot\displaystyle P_{tot} ≥ 0
dr\displaystyle d_{r}Déplacement relatif de calcul entre étagesmmdr\displaystyle d_{r} ≥ 0
Vtot\displaystyle V_{tot}Effort tranchant sismique total du niveaukNVtot\displaystyle V_{tot} > 0
h\displaystyle hHauteur d'étagemmh\displaystyle h > 0
θ\displaystyle θCoefficient de sensibilité au déplacement entre étages–Result

Exemple d’application

Ptot\displaystyle P_{tot} = 8 000 kN · dr\displaystyle d_{r} = 15 mm · Vtot\displaystyle V_{tot} = 500 kN · h\displaystyle h = 3 000 mm

θ\displaystyle θ = 0,08 · Source: Calcul manuel

Scope and standard

EN 1998-1, paragraphe 4.4.2.2 (effets du second ordre négligeables si theta <= 0,10).

Standard
EN 1998-1:2004, paragraphe 4.4.2.2, Eq. (4.28)
Result
θ\displaystyle θ (dimensionless)

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
θ\displaystyle θ = 0,08= ((8 000 kN) · (15 mm)) / ((500 kN) · (3 000 mm))

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

La recherche commence dans Actions et charges › Actions sismiques.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.