Progetto · Acciaio

Resistenza di progetto a trazione del bullone Ft,Rd

  • Tipo: Resistenza
  • Versione 1
  • revisionata il 09/11/2026

Resistenza di progetto a trazione di un bullone: Ft,Rd = k2 · fub · As / γM2.

Ft,Rd=k2⋅fub⋅AsγM2\displaystyle F_{t,\mathrm{Rd}} = \frac{k_{2} \cdot f_{ub} \cdot A_{s}}{\gamma_{\mathrm{M2}}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

Ft,RdAsfub

Formula and quantities

SymbolNameUnitNote
k2\displaystyle k_{2}Fattore del bullone–
fub\displaystyle f_{ub}Resistenza ultima a trazione del bulloneN/mm²
As\displaystyle A_{s}Area resistente a trazione del bullonem²
γM2\displaystyle \gamma_{\mathrm{M2}}Fattore parziale per i collegamenti–
Ft,Rd\displaystyle F_{t,\mathrm{Rd}}Resistenza di progetto a trazionekNResult

Esempio svolto

k2\displaystyle k_{2} = 0,9 · fub\displaystyle f_{ub} = 800 N/mm² · As\displaystyle A_{s} = 0,000245 m² · γM2\displaystyle \gamma_{\mathrm{M2}} = 1,25

Ft,Rd\displaystyle F_{t,\mathrm{Rd}} = 141,12 kN · Source: EN 1993-1-8:2005 Tabella 3.4

Scope and standard

Collegamenti bullonati a trazione secondo EN 1993-1-8, Tabella 3.4 (k_2 = 0,9 per bulloni standard).

Standard
EN 1993-1-8:2005, punto 3.6.1, Eq. Tabella 3.4
Result
Ft,Rd\displaystyle F_{t,\mathrm{Rd}} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Ft,Rd\displaystyle F_{t,\mathrm{Rd}} = 141,12 kN= 0,9 · (800 N/mm²) · (0,000245 m²) / 1,25

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

La ricerca parte in Progetto › Acciaio.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.