設計 · 複合構造

完全せん断結合に必要なスタッド本数 nf

  • タイプ:特性値
  • バージョン1
  • 2026/11/13にレビュー済み

完全せん断結合のために臨界区間に必要なシアコネクタ本数:nf = min(Ncf, Npl,a) / PRd。

nf=min(Ncf,Npl,a)/PRd\displaystyle n_{f} = min(N_{cf}, N_{\mathrm{pl},a}) / P_{\mathrm{Rd}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

PRdnf

Formula and quantities

SymbolNameUnitNote
Ncf\displaystyle N_{cf}コンクリートフランジの塑性圧縮耐力kN
Npl,a\displaystyle N_{\mathrm{pl},a}形鋼断面の塑性軸耐力kN
PRd\displaystyle P_{\mathrm{Rd}}シアコネクタ1本の設計せん断耐力kN
nf\displaystyle n_{f}必要シアコネクタ本数1Result

例題

Ncf\displaystyle N_{cf} = 4,080 kN · Npl,a\displaystyle N_{\mathrm{pl},a} = 2,580.85 kN · PRd\displaystyle P_{\mathrm{Rd}} = 81.66 kN

nf\displaystyle n_{f} = 31.6

Standard and source

Result
nf\displaystyle n_{f} in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
nf\displaystyle n_{f} = 31.6048 1= min((4,080 kN); (2,580.85 kN)) / (81.66 kN)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

検索は設計 › 複合構造で開始されます。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.