設計 · 複合構造
コンクリートフランジ有効幅 beff
スパン中央または中間支点における合成梁コンクリートフランジの全有効幅:beff = b0 + be1 + be2。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 外側シアコネクタ中心間距離 | mm | ||
| 側 1 のコンクリートフランジ有効幅 | mm | ||
| 側 2 のコンクリートフランジ有効幅 | mm | ||
| コンクリートフランジ全有効幅 | mm | Result |
例題
= 120 mm · = 1,000 mm · = 1,000 mm
= 2,120 mm
Standard and source
- Standard
- EN 1994-1-1:2004
- Result
- in mm
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
検索は設計 › 複合構造で開始されます。
Miaknows the formula catalog and asks for what is missing.