設計 · 接合部
すみ肉溶接の設計せん断強度 fvw,d
簡略法による鋼構造すみ肉溶接の設計せん断強度: fvw,d = (fu / √(3)) / (βw · γM2)。
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 接合される弱い方の部材の公称引張強さ | N/m² | ||
| 鋼種に対する相関係数 | 1 | ||
| 溶接継手に対する部分係数 | 1 | ||
| すみ肉溶接の設計せん断強度 | N/m² | Result |
例題
= 510,000,000 N/m² · = 0.9 · = 1.25
= 261,730,000 N/m²
Standard and source
- Standard
- EN 1993-1-8-2005-ac:2009
- Result
- in MPa
Reference to clause and equation, no standard text. The description is written in our own words.