設計 · 鋼構造

すみ肉溶接の設計せん断強度 fvw,d

  • タイプ:特性値
  • バージョン1
  • 2026/11/9にレビュー済み

簡易法によるすみ肉溶接の設計せん断強度:fvw,d = fu / (√3 · βw · γM2)。

fvw,d=fu3⋅βw⋅γM2\displaystyle f_{vw,\mathrm{d}} = \frac{f_{u}}{\sqrt{3} \cdot \beta_{w} \cdot \gamma_{\mathrm{M2}}}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

fufvw,dβw

Formula and quantities

SymbolNameUnitNote
fu\displaystyle f_{u}弱材の公称引張強度N/mm²
βw\displaystyle \beta_{w}すみ肉溶接の相関係数–
γM2\displaystyle \gamma_{\mathrm{M2}}接合部の部分係数–
fvw,d\displaystyle f_{vw,\mathrm{d}}溶接の設計せん断強度N/mm²Result

例題

fu\displaystyle f_{u} = 360 N/mm² · βw\displaystyle \beta_{w} = 0.8 · γM2\displaystyle \gamma_{\mathrm{M2}} = 1.25

fvw,d\displaystyle f_{vw,\mathrm{d}} = 207.846 N/mm² · Source: EN 1993-1-8:2005 式 (4.4)

Scope and standard

EN 1993-1-8 4.5.3.3項によるすみ肉溶接継手。

Standard
EN 1993-1-8:2005、4.5.3.3 (1)項、式 (4.4)
Result
fvw,d\displaystyle f_{vw,\mathrm{d}} in N/mm²

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
fvw,d\displaystyle f_{vw,\mathrm{d}} = 207.846 N/mm²= (360 N/mm²) / (sqrt(3) · 0.8 · 1.25)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

検索は設計 › 鋼構造で開始されます。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.