断面 · 組立断面
対称フランジカバープレートの断面二次モーメント寄与
高さ h の上下フランジに溶接された2枚の対称カバープレートによる強軸断面二次モーメント増加分: Ip = bp · tp³ / 6 + bp · tp · (h + tp)² / 2。
- General formula, independent of standards
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| カバープレート幅 | mm | ||
| カバープレート厚さ | mm | ||
| 基本断面のせい | mm | ||
| カバープレートの断面二次モーメント | cm⁴ | Result |
例題
= 200 mm · = 15 mm · = 300 mm
= 14,889.4 cm⁴
Standard and source
- Result
- in cm⁴
Reference to clause and equation, no standard text. The description is written in our own words.
Try it