断面 · 組立断面
帯板連結2弦材柱のせん断剛性
帯板で連結された2弦材圧縮部材のせん断剛性 Sv: Sv = (24 · E · Ich) / (a² · (1 + (2 · Ich · h0) / (n · Ib · a)))。
- General formula, independent of standards
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 弾性係数 | N/m² | ||
| 弦材1本の面内断面二次モーメント | cm⁴ | ||
| 帯板1枚の面内断面二次モーメント | cm⁴ | ||
| 帯板の中心間隔 | mm | ||
| 弦材図心間距離 | mm | ||
| 帯板面の数 | 1 | ||
| せん断剛性 | kN | Result |
例題
= 210,000,000,000 N/m² · = 200 cm⁴ · = 400 cm⁴ · = 800 mm · = 300 mm · = 2
= 13,263.2 kN
Standard and source
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
検索は断面 › 組立断面で開始されます。
Miaknows the formula catalog and asks for what is missing.