設計 · コンクリート構造

プレストレス分散長さ ldisp (EN 1992-1-1)

  • タイプ:特性値
  • バージョン1
  • 2026/11/25にレビュー済み

EN 1992-1-1 第8.10.2.2(4)項 式(8.19)によるコンクリート応力が断面高さ方向に線形分布に達する分散長さ: ldisp = √(lpt2² + d²).

ldisp=lpt22+d2\displaystyle l_{disp} = \sqrt{l_{pt2}^2 + d^2}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

ldisp

Formula and quantities

SymbolNameUnitNote
lpt2\displaystyle l_{pt2}伝達長さの上限設計値 (1.2 * l_pt)mm
d\displaystyle dコンクリート断面の有効高さmm
ldisp\displaystyle l_{disp}プレストレス分散長さmmResult

例題

lpt2\displaystyle l_{pt2} = 650 mm · d\displaystyle d = 220 mm

ldisp\displaystyle l_{disp} = 686.222 mm

Standard and source

Result
ldisp\displaystyle l_{disp} in mm

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
ldisp\displaystyle l_{disp} = 686.222 mm= sqrt((650 mm)² + (220 mm)²)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

検索は設計 › コンクリート構造で開始されます。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.