設計 · コンクリート構造

500°C 等温線法による低減有効せい (EN 1992-1-2)

  • タイプ:特性値
  • バージョン1
  • 2026/11/21にレビュー済み

EN 1992-1-2 附属書B.1による圧縮面または引張面が加熱されるコンクリート梁・スラブの低減有効せい dfi: dfi = d - a500.

dfi=d−a500\displaystyle d_{fi} = d - a_{500}
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

dfi

Formula and quantities

SymbolNameUnitNote
d\displaystyle d元の有効せいmm
a500\displaystyle a_{500}加熱圧縮面からの 500°C 等温線深さmm
dfi\displaystyle d_{fi}火災時低減有効せいmmResult

例題

d\displaystyle d = 550 mm · a500\displaystyle a_{500} = 35 mm

dfi\displaystyle d_{fi} = 515 mm

Standard and source

Result
dfi\displaystyle d_{fi} in mm

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
dfi\displaystyle d_{fi} = 515 mm= (550 mm) - (35 mm)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

検索は設計 › コンクリート構造で開始されます。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.