構造解析 · 柱と安定性
非変形架構における柱の有効長係数
EN 1993-1-1付属書Eによる非変形架構内の柱の有効長係数 beta の近似式:β = 0.5 · √((1 + 0.145 · (η1 + η2) - 0.265 · η1 · η2) / (2 - 0.364 · (η1 + η2) - 0.247 · η1 · η2))。
- General formula, independent of standards
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| 端部1の接合分配係数 | – | ||
| 端部2の接合分配係数 | – | ||
| 有効長係数 | – | Result |
例題
= 1 · = 1
= 0.5 · Source: 0.5 · sqrt((1 + 0.29 - 0.265) / (2 - 0.728 - 0.247)) = 0.5 · sqrt(1.025 / 1.025) = 0.5
Scope and standard
ブレースド/非変形建物架構内の柱。
- Result
- (dimensionless)
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
検索は構造解析 › 柱と安定性で開始されます。
Miaknows the formula catalog and asks for what is missing.