設計 · ガラス構造

複層ガラスの中空層係数 φ (EN 16612)

  • タイプ:特性値
  • バージョン1
  • 2026/11/25にレビュー済み

EN 16612 第7.3.2項によるガラス板間の中空層圧力連成を支配する複層ガラス係数 phi: φIGU = 1 / (1 + (a / astar)⁴).

ϕIGU=1/(1+(a/astar)4)\displaystyle \phi _{IGU} = 1 / (1 + (a / a_{star})^4)
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

φIGU

Formula and quantities

SymbolNameUnitNote
a\displaystyle aガラス板の短辺スパンmm
astar\displaystyle a_{star}複層ガラスユニットの特性長さmm
ϕIGU\displaystyle \phi_{IGU}複層ガラス係数1Result

例題

a\displaystyle a = 600 mm · astar\displaystyle a_{star} = 480 mm

ϕIGU\displaystyle \phi_{IGU} = 0.290579

Standard and source

Result
ϕIGU\displaystyle \phi_{IGU} in 1

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
ϕIGU\displaystyle \phi_{IGU} = 0.290579 1= 1 / (1 + ((600 mm) / (480 mm))⁴)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

検索は設計 › ガラス構造で開始されます。

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.