Cross-sections · Built-up sections

Shear stiffness of a single-laced two-chord column

  • Type: Property
  • Version 1
  • reviewed on 11/13/2026

Shear stiffness Sv of a two-chord built-up column with single diagonal lacing: Sv = (n · E · Ad · a · h0²) / (2 · d³).

Sv=(n⋅E⋅Ad⋅a⋅h02)/(2⋅d3)\displaystyle S_{v} = (n \cdot E \cdot A_{\mathrm{d}} \cdot a \cdot h_{0}^2) / (2 \cdot d^3)
  • General formula, independent of standards
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

a

Formula and quantities

SymbolNameUnitNote
n\displaystyle nNumber of planes of lacings1
E\displaystyle EModulus of elasticityN/m²
Ad\displaystyle A_{\mathrm{d}}Cross-sectional area of one diagonalmm²
a\displaystyle aPanel length between nodesmm
h0\displaystyle h_{0}Distance between chord centroidsmm
d\displaystyle dDiagonal member lengthmm
Sv\displaystyle S_{v}Shear stiffnesskNResult

Worked example

n\displaystyle n = 2 · E\displaystyle E = 210,000,000,000 N/m² · Ad\displaystyle A_{\mathrm{d}} = 500 mm² · a\displaystyle a = 400 mm · h0\displaystyle h_{0} = 300 mm · d\displaystyle d = 500 mm

Sv\displaystyle S_{v} = 30,240 kN

Standard and source

Result
Sv\displaystyle S_{v} in kN

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
Sv\displaystyle S_{v} = 30,240 kN= ((2 1) · (210,000,000,000 N/m²) · (500 mm²) · (400 mm) · (300 mm)²) / (2 · (500 mm)³)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Cross-sections › Built-up sections.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.