Cross-sections · Built-up sections
Shear stiffness of a battened two-chord column
Shear stiffness Sv of a two-chord battened compression member: Sv = (24 · E · Ich) / (a² · (1 + (2 · Ich · h0) / (n · Ib · a))).
- General formula, independent of standards
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Modulus of elasticity | N/m² | ||
| In-plane moment of inertia of one chord | cm⁴ | ||
| In-plane moment of inertia of one batten | cm⁴ | ||
| Center-to-center spacing of battens | mm | ||
| Distance between chord centroids | mm | ||
| Number of planes of battens | 1 | ||
| Shear stiffness | kN | Result |
Worked example
= 210,000,000,000 N/m² · = 200 cm⁴ · = 400 cm⁴ · = 800 mm · = 300 mm · = 2
= 13,263.2 kN
Standard and source
- Result
- in kN
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Calculate for my dimensionsenter values, check the result
- Compare with a catalog sectionformula value and table value
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Cross-sections › Built-up sections.
Miaknows the formula catalog and asks for what is missing.