Design · Glass

IGU isochoric pressure from altitude difference p0,H (EN 16612)

  • Type: Property
  • Version 1
  • reviewed on 11/25/2026

Isochoric cavity pressure generated by an installation altitude difference relative to the production plant according to EN 16612 Clause 7.3.3: p0H = cH · ΔH.

p0H=cH⋅ΔH\displaystyle p_{0H} = c_{H} \cdot \Delta H
Apply in CALC

Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.

p0H

Formula and quantities

SymbolNameUnitNote
cH\displaystyle c_{H}Altitude isochoric pressure coefficient (typically 0.012 kPa/m)N/m³
ΔH\displaystyle \Delta HAltitude difference between site and productionm
p0H\displaystyle p_{0H}Altitude-induced isochoric pressureN/m²Result

Worked example

cH\displaystyle c_{H} = 12 N/m³ · ΔH\displaystyle \Delta H = 600 m

p0H\displaystyle p_{0H} = 7,200 N/m²

Standard and source

Result
p0H\displaystyle p_{0H} in kPa

Reference to clause and equation, no standard text. The description is written in our own words.

Try it

Unit system
p0H\displaystyle p_{0H} = 7,200 N/m²= (12 N/m³) · (600 m)

Continue with Mia

Fills the input field in CALC; nothing is sent until you send it.

No matching formula yet? Find the right calculation rule.

Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.

The search starts in Design › Glass.

Miaknows the formula catalog and asks for what is missing.

You clarify missing information with Mia in the next step. Nothing is calculated yet.