Design · Glass
IGU isochoric pressure from altitude difference p0,H (EN 16612)
Isochoric cavity pressure generated by an installation altitude difference relative to the production plant according to EN 16612 Clause 7.3.3: p0H = cH · ΔH.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Altitude isochoric pressure coefficient (typically 0.012 kPa/m) | N/m³ | ||
| Altitude difference between site and production | m | ||
| Altitude-induced isochoric pressure | N/m² | Result |
Worked example
= 12 N/m³ · = 600 m
= 7,200 N/m²
Standard and source
- Standard
- EN 16612:2019
- Result
- in kPa
Reference to clause and equation, no standard text. The description is written in our own words.
Try it
Continue with Mia
- Explain the formulastep by step
- Calculate for my dimensionsenter values, check the result
- Compare with a catalog sectionformula value and table value
Fills the input field in CALC; nothing is sent until you send it.
No matching formula yet? Find the right calculation rule.
Describe what you want to determine. Mia searches the formula catalog first and clarifies assumptions before anything is calculated.
The search starts in Design › Glass.
Miaknows the formula catalog and asks for what is missing.