Design · Glass
IGU isochoric pressure from temperature change p0,T (EN 16612)
Isochoric cavity pressure generated by a temperature difference relative to manufacturing conditions according to EN 16612 Clause 7.3.3: p0T = cT · ΔT.
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Temperature isochoric pressure coefficient (kPa/K, typically 0.34) | N/m² | ||
| Cavity gas temperature change (in K) | 1 | ||
| Temperature-induced isochoric pressure | N/m² | Result |
Worked example
= 340 N/m² · = 20
= 6,800 N/m²
Standard and source
- Standard
- EN 16612:2019
- Result
- in kPa
Reference to clause and equation, no standard text. The description is written in our own words.