Timber design strength in fire fd,fi (EN 1995-1-2)
Design strength of timber in fire according to EN 1995-1-2 Clause 2.3 Eq. (2.1): fdfi = kmodfi · (kfi · fk) / γMfi.
- EN 1995-1-2:2004
Catalog formula, not a design. Check input values, coefficients, and limits against the standard and its national annex.
Formula and quantities
| Symbol | Name | Unit | Note |
|---|---|---|---|
| Modification factor for fire (1.0 for reduced cross-section method) | 1 | ||
| Coefficient from 5% to 20% fractile (1.25 solid timber, 1.15 glulam) | 1 | ||
| Characteristic timber strength (5% fractile) | N/m² | ||
| Partial factor for timber in fire (1.0) | 1 | ||
| Design timber strength in fire | N/m² | Result |
Worked example
= 1 1 · = 1.15 1 · = 24,000,000 N/m² · = 1 1
= 27,600,000 N/m²
Standard and source
- Standard
- EN 1995-1-2:2004
- Result
- in MPa
Reference to clause and equation, no standard text. The description is written in our own words.